{"id":14617,"date":"2025-01-28T17:36:21","date_gmt":"2025-01-28T16:36:21","guid":{"rendered":"https:\/\/bermellelectromedicina.com\/?p=14617"},"modified":"2025-01-28T17:41:31","modified_gmt":"2025-01-28T16:41:31","slug":"como-utilizar-moxy","status":"publish","type":"post","link":"https:\/\/bermellelectromedicina.com\/en\/como-utilizar-moxy\/","title":{"rendered":"\u00bfC\u00f3mo utilizar Moxy?"},"content":{"rendered":"\n<p>MOXY: <strong>Monitorizaci\u00f3n del ox\u00edgeno muscular durante el ejercicio<\/strong><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"636\" height=\"302\" src=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-1-Dispositivo.png\" alt=\"MOXY - el dispositivo\" class=\"wp-image-14609\" srcset=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-1-Dispositivo.png 636w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-1-Dispositivo-300x142.png 300w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-1-Dispositivo-150x71.png 150w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-1-Dispositivo-480x228.png 480w\" sizes=\"auto, (max-width:767px) 480px, 636px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">\u00bfQu\u00e9 mide Moxy?<\/h2>\n\n\n\n<p>Moxy mide cambios en la oxigenaci\u00f3n de la mioglobina a nivel capilar debidos al esfuerzo  f\u00edsico.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"507\" height=\"272\" src=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-2-Venas-y-arterias.png\" alt=\"Moxy - circulaci\u00f3n sangu\u00ednea en el m\u00fasculo\" class=\"wp-image-14611\" srcset=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-2-Venas-y-arterias.png 507w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-2-Venas-y-arterias-300x161.png 300w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-2-Venas-y-arterias-140x75.png 140w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-2-Venas-y-arterias-480x258.png 480w\" sizes=\"auto, (max-width:767px) 480px, 507px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center\">Mioglobina: Prote\u00edna de almacenamiento del ox\u00edgeno en el m\u00fasculo.<\/p>\n\n\n\n<p class=\"has-text-align-center\">Hemoglobina: Prote\u00edna de transporte del ox\u00edgeno al m\u00fasculo.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u00bfC\u00f3mo se mide?<\/h2>\n\n\n\n<p>Mediante las propiedades de la luz NIRS (espectro de luz pr\u00f3ximo al infrarrojo)<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"570\" height=\"189\" src=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-3-Espectro-luz-visible.png\" alt=\"MOXY - Espectro de luz visible\" class=\"wp-image-14613\" srcset=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-3-Espectro-luz-visible.png 570w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-3-Espectro-luz-visible-300x99.png 300w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-3-Espectro-luz-visible-150x50.png 150w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-3-Espectro-luz-visible-480x159.png 480w\" sizes=\"auto, (max-width:767px) 480px, 570px\" \/><\/figure>\n<\/div>\n\n\n<p>La luz NIRS viaja a trav\u00e9s de la piel, grasa y tejidos sin ser absorbida por completo. El resto de luz del espectro visible lo absorbe los tejidos.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"608\" height=\"340\" src=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-4-Medicion-O2.png\" alt=\"MOXY - C\u00f3mo se mide\" class=\"wp-image-14615\" srcset=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-4-Medicion-O2.png 608w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-4-Medicion-O2-300x168.png 300w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-4-Medicion-O2-134x75.png 134w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-4-Medicion-O2-480x268.png 480w\" sizes=\"auto, (max-width:767px) 480px, 608px\" \/><\/figure>\n<\/div>\n\n\n<p>El<strong> Emisor<\/strong> emite con diferentes longitudes de onda.<\/p>\n\n\n\n<p>La hemoglobina y la mioglobina absorben <strong>parte<\/strong> de la luz de determinadas longitudes de onda y de forma diferente en su forma oxigenada y desoxigenada.<\/p>\n\n\n\n<p>Los <strong>detectores<\/strong> miden la cantidad de luz no absorbida por la mioglobina y la hemoglobina.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u00bfD\u00f3nde se mide?<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"687\" height=\"453\" src=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-5-Donde-mide.png\" alt=\"MOXY - donde se mide\" class=\"wp-image-14597\" srcset=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-5-Donde-mide.png 687w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-5-Donde-mide-300x198.png 300w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-5-Donde-mide-114x75.png 114w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-5-Donde-mide-480x317.png 480w\" sizes=\"auto, (max-width:767px) 480px, 687px\" \/><\/figure>\n<\/div>\n\n\n<p><strong>En el m\u00fasculo activo<\/strong>. La mayor parte del haz de luz se pierde por dispersi\u00f3n, menos de una millon\u00e9sima parte llega al detector y se realiza la medida.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u00bfC\u00f3mo se expresa la medida?<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"567\" height=\"250\" src=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-6-Formula-SMO2.png\" alt=\"MOXY - SmO2\" class=\"wp-image-14599\" srcset=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-6-Formula-SMO2.png 567w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-6-Formula-SMO2-300x132.png 300w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-6-Formula-SMO2-150x66.png 150w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-6-Formula-SMO2-480x212.png 480w\" sizes=\"auto, (max-width:767px) 480px, 567px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"402\" height=\"378\" src=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-7-Arterias-y-venas-2.png\" alt=\"MOXY - Arterias y venas\" class=\"wp-image-14601\" srcset=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-7-Arterias-y-venas-2.png 402w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-7-Arterias-y-venas-2-300x282.png 300w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-7-Arterias-y-venas-2-80x75.png 80w\" sizes=\"auto, (max-width:767px) 402px, 402px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">En la pr\u00e1ctica<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"526\" height=\"340\" src=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-8-Practica.png\" alt=\"MOXY - En la pr\u00e1ctica\" class=\"wp-image-14603\" srcset=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-8-Practica.png 526w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-8-Practica-300x194.png 300w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-8-Practica-116x75.png 116w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-8-Practica-480x310.png 480w\" sizes=\"auto, (max-width:767px) 480px, 526px\" \/><\/figure>\n<\/div>\n\n\n<p><strong>MOXY<\/strong> mide el cambio din\u00e1mico de la <strong>SmO<sub>2<\/sub><\/strong> durante el ejercicio y los datos se interpretan mediante el comportamiento de la curva de la SmO<sub>2<\/sub> en funci\u00f3n de la intensidad del esfuerzo<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"554\" height=\"251\" src=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-9-grafico-smo2.png\" alt=\"MOXY - Curva de SmO2\" class=\"wp-image-14605\" srcset=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-9-grafico-smo2.png 554w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-9-grafico-smo2-300x136.png 300w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-9-grafico-smo2-150x68.png 150w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-9-grafico-smo2-480x217.png 480w\" sizes=\"auto, (max-width:767px) 480px, 554px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"490\" height=\"110\" src=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-11-info-del-SmO2.png\" alt=\"MOXY - Extracci\u00f3n O2\" class=\"wp-image-14620\" srcset=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-11-info-del-SmO2.png 490w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-11-info-del-SmO2-300x67.png 300w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-11-info-del-SmO2-150x34.png 150w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-11-info-del-SmO2-480x108.png 480w\" sizes=\"auto, (max-width:767px) 480px, 490px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"589\" height=\"283\" src=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-10-Grafico-2-smo2.png\" alt=\"MOXY - Pendientes en curva SmO2\" class=\"wp-image-14607\" srcset=\"https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-10-Grafico-2-smo2.png 589w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-10-Grafico-2-smo2-300x144.png 300w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-10-Grafico-2-smo2-150x72.png 150w, https:\/\/bermellelectromedicina.com\/wp-content\/uploads\/2025\/01\/Moxy-10-Grafico-2-smo2-480x231.png 480w\" sizes=\"auto, (max-width:767px) 480px, 589px\" \/><\/figure>\n<\/div>\n\n\n<p>Los cambios en la pendiente de la curva son m\u00e1s relevantes que el valor (% SmO<sub>2<\/sub>) de la se\u00f1al en s\u00ed. Es m\u00e1s relevante <strong>c\u00f3mo <\/strong>desciende la SmO<sub>2<\/sub> que <strong>cu\u00e1nto<\/strong> baja.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Para saber m\u00e1s<\/h2>\n\n\n\n<p>Crum, E. M., O&#8217;Connor, W. J., Van Loo, L., Valckx, M., &amp; Stannard, S. R. (2017). Validity and reliability of the Moxy oxygen monitor during incremental cycling exercise.&nbsp;<em>European journal of sport science<\/em>,&nbsp;<em>17<\/em>(8), 1037\u20131043. https:\/\/doi.org\/10.1080\/17461391.2017.1330899<\/p>\n\n\n\n<p>Feldmann, A. M., Erlacher, D., Pfister, S., &amp; Lehmann, R. (2020). Muscle oxygen dynamics in elite climbers during finger-hang tests at varying intensities.&nbsp;<em>Scientific reports<\/em>,&nbsp;<em>10<\/em>(1), 3040. https:\/\/doi.org\/10.1038\/s41598-020-60029-y<\/p>\n\n\n\n<p>Feldmann, A., Schmitz, R., &amp; Erlacher, D. (2019). Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor.&nbsp;<em>Journal of biomedical optics,<\/em>&nbsp;24(11), 1\u201311. https:\/\/doi.org\/10.1117\/1.JBO.24.11.115001<\/p>\n\n\n\n<p>McManus, C. J., Collison, J., &amp; Cooper, C. E. (2018). Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise.&nbsp;<em>Journal of biomedical optics<\/em>,&nbsp;<em>23<\/em>(1), 1\u201314. https:\/\/doi.org\/10.1117\/1.JBO.23.1.015007<\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>MOXY: Monitorizaci\u00f3n del ox\u00edgeno muscular durante el ejercicio \u00bfQu\u00e9 mide Moxy? Moxy mide cambios en la oxigenaci\u00f3n de la mioglobina a nivel capilar debidos al esfuerzo<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":3,"featured_media":14632,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-14617","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-deporte-y-salud"],"_links":{"self":[{"href":"https:\/\/bermellelectromedicina.com\/en\/wp-json\/wp\/v2\/posts\/14617","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bermellelectromedicina.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bermellelectromedicina.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bermellelectromedicina.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/bermellelectromedicina.com\/en\/wp-json\/wp\/v2\/comments?post=14617"}],"version-history":[{"count":6,"href":"https:\/\/bermellelectromedicina.com\/en\/wp-json\/wp\/v2\/posts\/14617\/revisions"}],"predecessor-version":[{"id":14637,"href":"https:\/\/bermellelectromedicina.com\/en\/wp-json\/wp\/v2\/posts\/14617\/revisions\/14637"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bermellelectromedicina.com\/en\/wp-json\/wp\/v2\/media\/14632"}],"wp:attachment":[{"href":"https:\/\/bermellelectromedicina.com\/en\/wp-json\/wp\/v2\/media?parent=14617"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bermellelectromedicina.com\/en\/wp-json\/wp\/v2\/categories?post=14617"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bermellelectromedicina.com\/en\/wp-json\/wp\/v2\/tags?post=14617"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}